FERC Accepts Additional PJM Capacity Market Design Changes

1714

The Federal Energy Regulatory Commission on Feb. 20 accepted PJM’s latest proposal to more accurately reflect current power supply-and-demand fundamentals in the capacity market.

The proposal (PDF), filed Dec. 20, 2024, eliminates the categorical exemption from the must-offer requirement for intermittent resources, capacity storage resources and hybrids beginning with the Base Residual Auction for the 2026/2027 Delivery Year, scheduled to take place in July. It also makes corresponding enhancements to the rules governing unit-specific Market Seller Offer Caps. The updates became effective Feb. 21.  

PJM said in its filing that the reforms will lead to capacity auction outcomes that more accurately reflect the actual quantity of existing generation capacity resources, while continuing to safeguard against the potential exercise of market power that may be exerted by the withholding of such resources.

The combined changes should result in additional resources being offered in the upcoming 2026/2027 Base Residual Auction, exerting downward pressure on prices while improving the reliability of the system.

Latest in a String of Rulings

The order is one of several in which FERC has agreed with PJM’s recommendations to address reliability and cost-effectiveness as PJM and stakeholders collaborate on longer-term solutions to address the imbalance of electricity supply and demand.

Each of the PJM proposals that FERC has recently approved serve to address – in the short term and/or long term – electricity supply shortages that threaten to drive wholesale prices up in the face of accelerating growth in electricity use.

Reliability Must-Run Resources and Cost of New (Generation) Entry

On Feb. 14, FERC accepted PJM’s proposal to recognize the capacity contribution of qualifying Reliability Must-Run units that may be reasonably expected to perform during capacity emergencies for the 2026/2027 and 2027/2028 delivery years. Reliability Must-Run units are generators that are asked to remain operating for a limited time beyond their intended retirement date to maintain system reliability.

In that same order, FERC also approved PJM’s proposal to maintain the gas-fired combustion turbine generation unit as the Reference Resource through the 2027/2028 Delivery Year. The retention of the combustion-turbine unit as the Reference Resource will ease consumer rate impacts, reduce market volatility, mitigate against the risk of a $0/MW-day Net Cost of New Entry (CONE), and still meet resource adequacy targets.

Resource Adequacy

On Feb. 11, FERC approved two PJM proposals to help boost the supply of electricity as the grid operator continues to work on the longer-term challenge of growing the generation fleet to keep up with accelerating electricity demand.

The Reliability Resource Initiative (RRI) is designed to get shovel-ready, high-reliability projects connected faster by adding them to the final transition cycle (Transition Cycle #2) of PJM’s reformed interconnection process, rather than waiting for the new cycle interconnection process to be fully implemented next year. The proposal (PDF) was filed with FERC Dec. 13, 2024.

The second initiative aims to streamline the use of Surplus Interconnection Service (SIS), or the unused portion of interconnection service for a facility that cannot or does not operate continuously, every hour of every day, year-round. An example of a pairing using SIS is a renewable resource combined with battery storage. The SIS filing (PDF) was made Dec. 20, 2024.

Board Warns of Capacity Shortage

PJM’s filings came after the PJM Board of Managers informed stakeholders of its support for undertaking immediate actions to provide for resource adequacy in light of the continuing and rapid tightening of grid power supplies versus growing demand for electricity.

A capacity shortage may affect the PJM system as early as the 2026/2027 Delivery Year, when the 2025 Long-Term Load Forecast is taken into account, PJM Board Chair Mark Takahashi noted in a Dec. 9 letter to stakeholders (PDF). 

Pending Filings

Two other filings await FERC’s ruling.

Capacity Interconnection Rights (CIR) Transfer Reforms

On Jan. 31, PJM filed with FERC a stakeholder-endorsed reform package (PDF) that will facilitate an expedited interconnection process for a replacement resource seeking to utilize the CIRs of a deactivating resource. As proposed, the Replacement Generation Interconnection Process would stand alone outside of the PJM cycle interconnection process and operate in parallel.PJM is requesting an effective date of April 2, 2025.

Price Cap and Floor

PJM on Feb. 20 filed with FERC to establish a price cap of approximately $325/MW-day in unforced capacity and a price floor of approximately $175/MW-day, both in unforced capacity (UCAP) for all capacity auctions for the 2026/2027 and 2027/2028 delivery years. PJM is proposing the temporary measures as components of an agreement with Pennsylvania Gov. Josh Shapiro. They are “designed to strike a balance between allowing the market to respond to increases in supply (which would normally lower prices) and maintaining a stable price signal that encourages long-term investment,” PJM stated in the filing. PJM requests an effective day of March 31, 2025.